As you know, the CDCS certificate is hard to get for most people. But our CDCS study guide will offer you the most professional guidance. As old saying goes, opportunities are always for those who prepare themselves well. In the end, you will easily pass the CDCS Exam through our assistance. Then you will find that your work ability is elevated greatly by studying our CDCS actual exam. In the end, you will become an excellent talent.
Now many IT professionals agree that EXIN certification CDCS exam certificate is a stepping stone to the peak of the IT industry. EXIN Certification CDCS Exam is an exam concerned by lots of IT professionals.
>> EXIN CDCS Test Score Report <<
Our CDCS cram materials will help you gain the success in your career. You can be respected and enjoy the great fame among the industry. When applying for the jobs your resumes will be browsed for many times and paid high attention to. The odds to succeed in the job interview will increase. So you could see the detailed information of our CDCS Exam Questions before you decide to buy them.
NEW QUESTION # 34
You need to determine the strategy for the cooling audit. All the servers are based on a front-to-rear (F-R) airflow design.
Which location for the temperature/humidity measurement should you recommend for the audit?
Answer: B
Explanation:
For a cooling audit in a data center, it is essential to measure temperature and humidity where air enters the servers to accurately assess cooling performance. In this case, since all servers have a front-to-rear (F-R) airflow design, measuring at the front/intake of the server will provide a precise understanding of the cooling conditions that the equipment is experiencing.
Detailed Explanation:
Servers with a front-to-rear airflow design draw in cool air from the cold aisle at the front, which is then exhausted into the hot aisle at the rear. By measuring temperature and humidity 50 mm/2 inches from the front intake, you gather data on the air conditions right before it enters the servers, providing an accurate representation of the cooling environment as it directly impacts the equipment.
Measuring in the cold aisle at the front intake ensures that the readings reflect the actual conditions of the incoming air that the servers depend on for effective cooling. This approach is consistent with best practices for maintaining thermal conditions in a data center, as it helps confirm that the cooling systems are delivering air within the required temperature and humidity specifications.
EPI Data Center Specialist References:
According to the EPI Data Center Specialist curriculum, the optimal placement for temperature and humidity sensors is at the intake of the equipment in the cold aisle, as it directly correlates to the environmental conditions affecting the servers. This positioning allows for a more effective audit of cooling performance, which is critical for maintaining the reliability and efficiency of the data center's operations.
NEW QUESTION # 35
A 5kW (power consumption) server keeps crashing with the message 'temperature too high'.
The intake temperature is measured at 25 °C/77 °F and a relative humidity (RH) level of 50%.
The exhaust temperature is 29 °C/84 °F and 45% RH.
The raised floor is providing an adequate amount of CFM/CMH at a reasonable velocity.
The pressure under the raised floor is approximately 25 Pa/0.1 inch H₂O.
Analyze the situation and indicate what the most likely cause is for this server to crash.
Answer: D
Explanation:
The server's repeated overheating despite adequate intake and exhaust temperatures suggests that dust buildup inside the server may be impeding heat transfer. Dust accumulation can obstruct airflow within the server, insulate components, and disrupt the convection-based cooling systems that regulate internal temperatures, leading to overheating and potential hardware failures.
Detailed Explanation:
While the intake and exhaust temperatures appear within acceptable ranges, internal dust can reduce airflow and impede cooling efficiency, causing internal components to overheat despite seemingly normal ambient conditions. Regular cleaning and maintenance are critical for preventing dust-related issues, especially in high-powered equipment like a 5kW server.
EPI Data Center Specialist References:
EPI emphasizes regular maintenance to prevent dust buildup in data center equipment. Dust can significantly impact cooling efficiency and lead to overheating, which underlines the importance of routine cleaning for optimal server performance.
NEW QUESTION # 36
What is a significant difference between a halocarbon gas-based fire suppression system and an inert gas-based fire suppression system?
Answer: C
Explanation:
A halocarbon gas-based fire suppression system primarily extinguishes fires through heat absorption. In contrast, an inert gas-based system works by reducing oxygen levels to a point where combustion cannot be sustained. Halocarbon agents, like FM-200, absorb heat from the fire, cooling it down, whereas inert gases, like nitrogen or argon, lower oxygen concentration.
Detailed Explanation:
Halocarbons are effective in quickly cooling flames and are suitable for electronic environments due to their fast action. Inert gases displace oxygen to suppress fires, making them ideal in occupied spaces where human safety can be managed during a fire event due to slower discharge times.
EPI Data Center Specialist References:
EPI training distinguishes between these suppression mechanisms, noting the importance of selecting the correct system based on specific needs like quick response versus oxygen displacement for environments with sensitive equipment.
NEW QUESTION # 37
A data center scores Rated-3 in mechanical, Rated-4 in electrical, and Rated-2 in architectural.
What is the overall Rating of this data center when the Rating is based on the ANSI/TIA-942?
Answer: C
Explanation:
According to ANSI/TIA-942 standards, the overall data center rating is determined by the lowest rating among all evaluated categories. Therefore, if a data center is rated 2 in architectural, despite being rated higher in mechanical and electrical, the overall rating is Rated-2. This approach ensures that all aspects meet a minimum standard and prevents a higher rating if any critical area does not comply.
Detailed Explanation:
ANSI/TIA-942 evaluates data centers across several areas, including mechanical, electrical, architectural, and telecommunications. The overall rating reflects the lowest rated category, ensuring that no aspect of the data center's design or operation falls below the specified level. Thus, in this case, the architectural rating of 2 dictates the final rating, ensuring a comprehensive and balanced assessment of reliability and resilience across all aspects.
EPI Data Center Specialist References:
EPI Data Center Specialist training aligns with ANSI/TIA-942, stating that the final rating must reflect the lowest score to ensure comprehensive reliability across all critical infrastructure categories. This avoids overstating the data center's resilience and ensures uniform standards across areas.
NEW QUESTION # 38
An MCB needs to be installed in the PDU of an air-conditioner unit.
Which breaking curve should you select?
Answer: B
Explanation:
For an MCB (Miniature Circuit Breaker) in the PDU of an air-conditioning unit, a C-Curve is recommended. C-Curve breakers are suitable for circuits with moderate inrush currents, such as those experienced in air conditioning units. They provide protection against overloads while accommodating the inrush without nuisance tripping.
Detailed Explanation:
C-Curve breakers trip when currents exceed 5 to 10 times the rated current, making them ideal for devices like air conditioners that experience moderate inrush currents upon startup. This characteristic provides a balance between protection and resilience against startup surges, preventing unnecessary trips while safeguarding the circuit.
EPI Data Center Specialist References:
EPI guidance for data center electrical systems specifies that C-Curve breakers are appropriate for equipment with inrush characteristics similar to air conditioning units, as they help prevent operational interruptions caused by typical surges during equipment start-up.
NEW QUESTION # 39
......
This society is ever – changing and the test content will change with the change of society. You don't have to worry that our CDCS training materials will be out of date. In order to keep up with the change direction of the CDCS Exam, our question bank has been constantly updated. We have dedicated IT staff that checks for updates of our CDCS study questions every day and sends them to you automatically once they occur.
New CDCS Test Simulator: https://www.testinsides.top/CDCS-dumps-review.html
With the development of society and the perfection of relative laws and regulations, the CDCS certificate in our career field becomes a necessity for our country, How our EXIN New CDCS Test Simulator New CDCS Test Simulator candidates pass The real exam questions that are being offered for on TestInsides New CDCS Test Simulator are the main reason for EXIN New CDCS Test Simulator success of most of the candidates who take our EXIN New CDCS Test Simulator New CDCS Test Simulator exam material, A good news you need to know is that once you buy our CDCS cram PDF, you will get the preferential treatment that your CDCS exam guide materials can be renewed in a year for free, which is ensured by our products but not exactly provided by other similar CDCS exam torrent: EXIN EPI Certified Data Centre Specialist.
How to implement a class's attributes as instance CDCS variables and properties, What Internet connectivity will your firewall prevent, With the development of society and the perfection of relative laws and regulations, the CDCS certificate in our career field becomes a necessity for our country.
How our EXIN EPI Data Centre candidates pass The real exam questions that are New CDCS Dumps Files being offered for on TestInsides are the main reason for EXIN success of most of the candidates who take our EXIN EPI Data Centre exam material.
A good news you need to know is that once you buy our CDCS cram PDF, you will get the preferential treatment that your CDCS exam guide materials can be renewed in a year for free, which is ensured by our products but not exactly provided by other similar CDCS exam torrent: EXIN EPI Certified Data Centre Specialist.
Thoughtful aftersales, Less time.
P.S. Free 2025 EXIN CDCS dumps are available on Google Drive shared by TestInsides: https://drive.google.com/open?id=1ne8aNxtwRScnM7nAEBjHkFn9-9yl4xUn